top of page

Phonon Equipment  is compact portable and easy-to-instal modular equipment:

Phonon software, Control computer, Data acquisition module, Magnetic holder,  Radio Synchronisation module and Phonon emission transducer

Transducers detect signals from phonon emission sources

Phonon software processes signals and localises position of the sources on the component

100% coverage of volume and surface of the inspected component

 

PHONON DIAGNOSTICS EQUIPMENT

Phonon Diagnostics Technique 

is based on a real-time diagnostics of physics process which goes in material and structure of facilities

 

PHONON DIAGNOSTICS

bgImage

PHONON EMISSION

The result of interaction of energy and material are various physical processes taking place in the material: stress concentration, deformation, corrosion, fatigue damage, destructions. 

Phonon emission appears on areas of defects formation and growth, said another way of hazardous operating conditions 

Phonon inspection consists in acquisition, recording, processing, analyzing and interpreting characteristic and factors of phonon emission propagation



ENERGY +  MATERIAL = PHONON EMISSION

Inspection without interference in the operating process  

Real-time inspection

Hard-to-reach facilities inspection

100% coverage of the inspected object

POD≥80% accuracy results:


Quantity

Location

Size

Type

Severity

Corrosion, Crack & Leak

Final report on technical state of facility, remaining life estimation following the inspection results.

Estimation of further operating conditions. 

3D modeling

BENEFITS FOR CUSTOMERS

Minimum of preparatory work

Safe and Continuous operation of facilities

Non-intrusive inspection technique

Increased speed of inspection

Financial saving

TECHNICAL CAPABILITIES

DEFECT DETECTION 

 

PHONON INSPECTION:  PIPELI​NES 

Above ground, underground & underwater, including hard-to-reach pipelines

PLANAR MODE:  

Inspection from one point only. Max. length of the inspected segment is about 500m, for more length to be studied each case.

LINEAR MODE: 

Inspection from two points simultaneously (start and end points). Max. length of the inspected segment is up to 1 km, for more length to be studied each case.

 

- 100% coverage of the inspected pipeline

- Real-time data acquisition

- Inspection without change of operating mode

Sal de cristal

Capacity facilities of any type  without changing of filling level

TANK INSPECTION:  

In-service, fast and 100% coverage, including tank shell, tank bottom, and tank roof

PRESSURE VESSEL INSPECTION

In-service, fast and 100% coverage of the inspected vessel 


-  Any geometric shape

- 100% coverage

- Real-time data acquisition

- Inspection without emptying, without change of operating mode

PHONON INSPECTION: PRESSURE VESSELS, TANKS

1. PREPARATION: 

Preparation of obtaining of information that will be used to design the facility mathematical model, selection of configuration, presettings and theoretical calibration, mobilisation of inspectors and phonon equipment.

2. PRELIMINARY INSPECTION: 

Updating or settings and performing calibration of equipment, processing and analysis of phonon diagnostics data on site.

3 . PHONON MONITORING:

Real-time data acquisition using phonon equipment.

4. PHONON DATA PROCESSING

Processing and analysis of the gathered data, final reports preparation.

 

Phonon Diagnostics is verified by the main oil and gas operators around the world 

PHONON INSPECTION STEPS

CONTACT US

Name and Surname*

Corporative email address*

Phone number*

Message*

Thanks! Your message has been sent successfully.

© 2024 Phonon Diagnostics. All rights reserved. 